EAGLE CHEMICAL CO INC -- SILICON GEL -- 6850-00-935-9797
=====================  Product Identification  =====================

Product ID:SILICON GEL
MSDS Date:12/21/1988
FSC:6850
NIIN:00-935-9797
=== Responsible Party ===
Company Name:EAGLE CHEMICAL CO INC
Address:TELEGRAPH & EAGLE DR
Box:107
City:MOBILE
State:AL
ZIP:36601
Country:US
Info Phone Num:205-452-9624
Emergency Phone Num:205-452-9624
CAGE:18425
=== Contractor Identification ===
Company Name:EAGLE CHEMICAL CO INC
Address:1500 TELEGRAPH RD
Box:107
City:MOBILE
State:AL
ZIP:36601
Country:US
Phone:334-452-9624
CAGE:18425

=============  Composition/Information on Ingredients  =============

Ingred Name:SILICA, AMORPHOUS, PRECIPITATED AND GEL
CAS:7699-41-4
RTECS #:VV8850000
Fraction by Wt: > 99% %
Other REC Limits:NONE RECOMMENDED
OSHA PEL:20 MPPCF
ACGIH TLV:10 MG/M3 TDUST; 9293

Ingred Name:QUARTZ, SILICON DIOXIDE
CAS:1317-79-9
Fraction by Wt: < 1% %
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50 (RAT) IS EST. >31,600 MG/KG
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE, SKIN & RESPIRATORY TRACT
    IRRITATION. CHRONIC: THE DRYING ACTION OF THIS MATERIAL CAN CAUSE
    IRRITATION OF THE MUCOUS MEMBRANES OF THE NOSE AND THROAT AND
    IRRITATION OF THE SKIN. AVOID PROLO NGED BREATHING OF THE DUST OR
    CONTACT OF DUST WITH THE SKIN.
Explanation of Carcinogenicity:THIS PRODUCT AND ITS COMPONENTS ARE NOT
    LISTED ON THE IARC, NTP OR OSHA CARCINOGENS LISTS.
Effects of Overexposure:MAY CAUSE EYE, SKIN & RESPIRATORY TRACT
    IRRITATION.
Medical Cond Aggravated by Exposure:MANUFACTURER KNOWS OF NO MEDICAL
    CONDITIONS ABNORMALLY AGGRAVATED BY EXPOSURE TO SILICA GEL.

=======================  First Aid Measures  =======================

First Aid:EYES: IMMEDIATELY WASH FROM EYES WITH LARGE AMOUNTS OF WATER,
    OCCASIONALLY LIFTING THE UPPER & LOWER EYE LIDS. IF IRRITATION
    OCCURS AND PERSISTS, SEEK MEDICAL ATTENTION. SKIN: WASH WITH SOAP
    AND WATER . INGESTION: MATERIAL WILL PASS THROUGHTHE BODY NORMALLY.
    INHALATION: REMOVE TO FRESH AIR.

=====================  Fire Fighting Measures  =====================

Flash Point:NONFLAMMABLE
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:NONFLAMMABLE. USE WATER FOG, CARBON DIOXIDE, FOAM,
    OR DRY CHEMICAL AS APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
    FULL FACED SELF CONTAINED BREATHING APPARATUS. COOL FIRE EXPOSED
    CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:COMBUSTION OR HEAT OF FIRE MAY PRODUCE
    HAZARDOUS DECOMPOSITION PRODUCTS AND VAPORS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SWEEP OR VACUUM UP OR FLUSH TO SEWER.
Neutralizing Agent:NONE REQUIRED

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID PROLONGED BREATHING OF THE DUST
    OR CONTACT OF DUST WITH THE SKIN. WHEN HANDLING, WEAR LONG SLEEVES
    AND CLOSE-WEAVE COTTON GLOVES WITH WRISTBANDS
Other Precautions:WEAR GOGGLES IF DUST CAUSES EYE DISCOMFORT. WEAR A
    PROPERLY FITTED NIOSH-APPROVED DUST RESPIRATOR FOR DUSTY
    CONDITIONS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:WEAR A PROPERLY FITTED NIOSH/MSHA APPROVED DUST
    RESPIRATOR IF CONDITIONS ARE DUSTY.
Ventilation:MECHANICAL(GENERAL) VENTILATION IS USUALLY ADEQUATE TO
    MAINTAIN DUST LEVELS BELOW TLV FOR NUISANCE DUST.
Protective Gloves:CLOSE-WEAVE COTTON WITH TIGHT WRISTBANDS
Eye Protection:GOGGLES FOR DUSTY CONDITIONS
Other Protective Equipment:LONG SLEEVED WORK CLOTHING.
Work Hygienic Practices:WASH THOROUGHLY AFTER USE AND BEFORE EATING,
    DRINKING OR SMOKING. VACUUM UP ANY DUST. LAUNDER CLOTHING BEFORE
    REUSE.
Supplemental Safety and Health
SILICA GEL IS A SYNTHETIC AMORPHOUS SILICA NOT TO BE CONFUSED WITH
    CRYSTALLINE SILICA. EPIDEMIOLOGICAL STUDIES INDICATE LOW POTENTIAL
    FOR ADVERSE HEALTH EFFECTS. SILICA GEL IS CONSIDERED TO BE A NUISA
    NCE DUST. IN THE ACTIVATED FORM, SILICAGEL ACTS AS A DESICCANT &
    CAN CAUSE A DRYING IRRITATION OF THE MUCOUS MEMBRANES.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:NOT GIVEN
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Vapor Pres:NOT GIVEN
Vapor Density:NOT GIVEN
Spec Gravity:1.1
Evaporation Rate & Reference:NIL
Solubility in Water:INSOLUBLE
Appearance and Odor:CRYSTALLINE, NO ODOR
Percent Volatiles by Volume:NIL

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:HIGH HEAT, OPEN FLAMES AND OTHER SOURCES
    OF IGNITION
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE IN AN APPROVED LANDFILL ACCORDING TO
    LOCAL, STATE AND FEDERAL REGULATIONS. COVER PROMPTLY TO AVOID
    BLOWING DUST.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.